Installing, configuring, handling, and troubleshooting NSX-T Data Center 3.0 solutions should be 6 months or more of experience for the minimally eligible applicant. Candidates who are well aware of NSX-T characteristics, functions, and architectures should take this exam. People with at least 6 months of Linux and KVM hands-on experience are highly encouraged to apply for this certification as this will give them an edge. In IT and with VMware vSphere and its command line, they should have 1 year of experience operating. Additional industry-recognized IT certifications or accreditation would likely be held by the successful applicant. All the information found in the exam sections mentioned below should be in the MQC.
NEW QUESTION 30
What is the most restrictive NSX-T built-in role which will allow a user to apply configuration changes on a NSX Edge?
- A. Network Engineer
- B. NSX Administrator
- C. Network Operator
- D. Cloud Service Administrator
Answer: A
NEW QUESTION 31
What are the advantages of using a Tier-0 Gateway in ECMP mode? (Choose two.)
- A. increased north/south bandwidth
- B. traffic load balancing
- C. stateful services leveraged
- D. traffic predictability
- E. Failover of services
Answer: A,B
NEW QUESTION 32
Where are Distributed Firewall logs containing access decisions stored?
- A. NSX API
- B. NSX Edge
- C. NSX Manager
- D. Hypervisor transport node
Answer: C
NEW QUESTION 33
Which three functions require a Services Router (SR) component on an Edge node? (Choose three.)
- A. Distributed Routing
- B. Distributed Firewall
- C. Virtual Private Network
- D. Service Insertion
- E. Gateway Firewall
- F. Packet Forwarding
Answer: C,D,E
NEW QUESTION 34
What are two supported N-VDS modes? (Choose two.)
- A. Secure Datapath
- B. Enhanced Datapath
- C. Standard Datapath
- D. DPDK Datapath
- E. Overlay Datapath
Answer: B,C
Explanation:
Reference:
https://docs.vmware.com/en/VMware-NSX-T-Data-Center/3.0/installation/GUID-37BC3CEF-DCC1-4C6F-960D-CFBB31908D1C.html
NEW QUESTION 35
What are three NSX Manager roles? (Choose three.)
- A. zookeeper
- B. cloud
- C. manager
- D. policy
- E. controller
- F. master
Answer: C,D,E
NEW QUESTION 36
How is the RouterLink port created between a Tier-1 Gateway and Tier-0 Gateway?
- A. Automatically created when Tier-1 is connected with Tier-0 from NSX UI.
- B. Automatically created when Tier-1 is created.
- C. Manually create a Segment and connect to both Tier-1 and Tier-0 Gateways.
- D. Manually create a Logical Switch and connect to bother Tier-1 and Tier-0 Gateways.
Answer: A
Explanation:
Explanation
https://docs.vmware.com/en/VMware-NSX-T-Data-Center/3.0/administration/GUID-3F163DEE-1EE6-4D80-BE
NEW QUESTION 37
Which statement is true about an alarm in a Suppressed state?
- A. An alarm can be suppressed for a specific duration in days.
- B. An alarm can be suppressed for a specific duration in minutes.
- C. An alarm can be suppressed for a specific duration in hours.
- D. An alarm can be suppressed for a specific duration in seconds.
Answer: A
NEW QUESTION 38
When running nsxcli on an ESXi host, which command will show the Replication mode?
- A. get logical-switch <Local-Switch-UUID> status
- B. get logical-switch <Logical-Switch-UUID>
- C. get logical-switch status
- D. get logical-switches
Answer: B
Explanation:
Explanation
https://vdc-download.vmware.com/vmwb-repository/dcr-public/cc42e3c1-eb34-4567-a916-147e79798957/82646
NEW QUESTION 39
Which two BGP configuration parameters can be configured in the VRF Lite gateways? (Choose two.)
- A. BGP Neighbors
- B. Route Aggregation
- C. Graceful Restart
- D. Local AS
The following parameters are inherited from the default Tier-0 gateway and cannot be modified at the VRF level:
* Local AS
* Graceful restart
* Graceful restart timer
* Graceful restart stale timer
* Multipath relax
Inter-SR iBGP is not supported in VRF gateways.
BGP can be enabled or disabled per VRF gateway.
Route aggregation and BGP neighbors are local configurations per VRF. - E. Route Distribution
Answer: A,B
NEW QUESTION 40
Which two statements describe the characteristics of an Edge Cluster in NSX-T 3.0 Data Center? (Choose two.)
- A. can have a maximum of 8 edge nodes
- B. must contain only one type of edge nodes (VM or bare metal)
- C. must have only active-active edge nodes
- D. can have a maximum of 10 edge nodes
- E. can contain multiple types of edge nodes (VM or bare metal)
Answer: D,E
Explanation:
Reference:
https://docs.vmware.com/en/VMware-NSX-T-Data-Center/3.0/installation/GUID-14183A62-8E8D-43CC-92E0-E8D72E198D5A.html
NEW QUESTION 41
Which statement describes the VMware Virtual Cloud Network Vision?
- A. Virtual Cloud Network connects and protects virtual machines running in vSphere environments.
- B. Virtual Cloud Network connects and protects virtual machines running in KVM environments.
- C. Virtual Cloud Network connects and protects applications and data, regardless of their physical locations.
- D. Virtual Cloud Network connects and protects applications, regardless of their physical locations.
Answer: C
NEW QUESTION 42
An NSX administrator wants to create a Tier-0 Gateway to support equal cost multi-path (ECMP) routing.
Which failover detection protocol must be used to meet this requirement?
- A. Bidirectional Forwarding Detection (BFD)
- B. Beacon Probing (BP)
- C. Host Standby Router Protocol (HSRP)
- D. Virtual Router Redundancy Protocol (VRRP)
Answer: A
NEW QUESTION 43
Which statement Is true regarding the audit user account? (Choose two.)
- A. The audit user has read-write access to the NSX Manager.
- B. The administrator must run the set audit user password <password> command.
- C. The admin user must set the password for the audit account to log in to NSX Manager.
- D. The audit user is disabled by default and must be enabled to log in to the NSX Manager.
- E. The administrator must run the set user audit password <password> command.
Answer: C,E
NEW QUESTION 44
An NSX administrator noticed that the nsxcli command times out after 600 secs of idle time.
Which CLI command disables the nsxcli time out value on NSX Manager?
- A. set cli-timeout 0
- B. set cli-timeout enabled
- C. set cli-timeout disabled
- D. set cli-timeout 1
Answer: A
Explanation:
Explanation
"
https://vdc-download.vmware.com/vmwb-repository/dcr-public/cc42e3c1-eb34-4567-a916-147e79798957/82646
https://www.virten.net/2020/06/quick-tip-remove-nsx-t-ssh-and-http-session-timeout/
NEW QUESTION 45
Which three protocols could an NSX administrator use to transfer log messages to a remote log server?
(Choose three.)
- A. SSL
- B. UDP
- C. SSH
- D. HTTPS
- E. TLS
- F. TCP
Answer: B,E,F
Explanation:
Explanation
https://www.vmware.com/content/dam/digitalmarketing/vmware/en/pdf/certification/vmware-2vo-41.20-exam-p
NEW QUESTION 46
Which two statements describe the characteristics of an Edge Cluster in NSX-T 3.0 Data Center? (Choose two.)
- A. can have a maximum of 8 edge nodes
- B. must contain only one type of edge nodes (VM or bare metal)
- C. must have only active-active edge nodes
- D. can have a maximum of 10 edge nodes
- E. can contain multiple types of edge nodes (VM or bare metal)
Answer: D,E
NEW QUESTION 47
An NSX administrator is using ping to check connectivity between VM1 running on ESXi1 to VM2 running on ESXi2. The ping tests fails. The administrator knows the maximum transmission unit size on the physical switch is 1600.
Which command does the administrator use to check the VMware kernel ports for tunnel end point communication?
- A. esxcli network diag ping -I vmk0 -H <destination IP address>
https://kb.vmware.com/s/article/1003728 - B. vmkping ++netstack=geneve -d -s 1572 <destination IP address>
- C. esxcli network diag ping -H <destination IP address>
- D. vmkping ++netstack=vxlan-d -s 1572 <destination IP address>
Answer: D
NEW QUESTION 48
Which discovery protocol is supported for hypervisor transport nodes?
- A. Neighbor Discovery Protocol
- B. Adobe Real-time CDP
- C. Link Layer Discovery Protocol
- D. Cisco Discovery Protocol
Answer: C
NEW QUESTION 49
Which two statements describe the characteristics of an Edge Cluster in NSX-T 3.0 Data Center? (Choose two.)
- A. can have a maximum of 8 edge nodes
- B. must contain only one type of edge nodes (VM or bare metal)
- C. must have only active-active edge nodes
- D. can have a maximum of 10 edge nodes
- E. can contain multiple types of edge nodes (VM or bare metal)
Answer: D,E
Explanation:
Explanation
NEW QUESTION 50
An NSX administrator is configuring the KVM hypervisor host as a transport node and wants to apply the Failover Order as a NIC teaming policy.
Which profile allows the administrator to configure the NIC Teaming policy as Failover Order?
- A. Uplink Profile
- B. N-VDS/VDS Profile
- C. Host Switch Profile
- D. Transport Node Profile
Answer: A
NEW QUESTION 51
An NSX administrator noticed that the nsxcli command times out after 600 secs of idle time.
Which CLI command disables the nsxcli time out value on NSX Manager?
- A. set cli-timeout 0
- B. set cli-timeout enabled
- C. set cli-timeout disabled
- D. set cli-timeout 1
Answer: A
Explanation:
Reference:
" https://vdc-download.vmware.com/vmwb-repository/dcr-public/cc42e3c1-eb34-4567-a916-147e79798957/8264605c-a5e1-49a8-b603-cc78621eeeab/cli.html#set%20cli-timeout%20%3Ctimeout%3E
https://www.virten.net/2020/06/quick-tip-remove-nsx-t-ssh-and-http-session-timeout/
NEW QUESTION 52
Which two ports are used by a transport node to communicate with the management and control planes in NSX-T Data Center 3.0? (Choose two.)
- A. 0
- B. 1
- C. 2
- D. 3
- E. 4
Answer: A,E
NEW QUESTION 53
Which network tool cloud an administrator use on an ESXi 7 host to capture packets when troubleshooting connectivity issues?
- A. Wireshark
- B. net-stats
- C. pktcap-uw
- D. tcpdump
Answer: C
Explanation:
If you do when troubleshooting connectivity issues on your Virtualization environment. This post will help you to capture Network traffic on ESXi host using pktcap-uw tool.
NEW QUESTION 54
......
For more info read reference:
Valid 2V0-41.20 Exam Dumps Ensure you a HIGH SCORE: https://www.practicevce.com/VMware/2V0-41.20-practice-exam-dumps.html